精品久久人妻av中文字幕_国产精品毛片久久久久久久_一本之道高清无码视频_国产乱人伦真实精品视频

Product Detail
Share to:
6CCG-90D bottle type fried dryer
價格:
13,500.00
規格: 1750×1100×1700
顏色: light grey
品牌: Linon
型號: 6CCG-90D
市場價: 13,800.00
Quantity:
Detail
Review(0)



main feature

A. Use automatic constant temperature system, equipped with automatic temperature control ignition device.

B. The thermal insulation material adopts special thermal insulation material to better prevent the heat from escaping, thereby achieving the purpose of rapid temperature rise and gas saving.

C. The rotating drum adopts advanced stepless speed regulation, the tea is quick and clean, the speed control operation is flexible and convenient, and the operation is stable, which is suitable for the frying of various types of tea.

D. The use of imported infrared metal mesh burners has the advantages of uniform fire and high production rate.

3, the main components

It consists of main components such as frame, inner drum, outer cylinder, stepless speed regulating motor, gearbox and liquefied gas exhaust.

Operating procedure

1. It is necessary to configure the wire and the knife switch corresponding to the power of the green machine.

2. The motor steering should be consistent with the steering indicated by the frying machine control box.

3. The liquefied gas is used in the frying machine. In order to ensure safe production, it is strictly prohibited to install it in a place with poor ventilation. If it is installed in a room, windows or other ventilation devices must be guaranteed.

4. The parallel points of the drum should be adjusted so that the inner tank is in a horizontal position.

5. The gas valve adjustment bolt should be adjusted at a position with a large pressure, and the pressure in the clockwise direction is increased.

6. The output of the igniter is ultra-high voltage. Pay attention to prevent electric shock during maintenance and debugging.

7. When stopping, stop heating first, then cut off the power.

Installation and maintenance

1. Regularly add the lubrication parts and tighten the fixing screws and bolts.

2. After the end of the tea season, check the gearbox oil quantity, fill or replace the oil;

3. For a period of time, the burner nozzle and the gas pipe should be descaled.

4. Check the wear and tightness of the drive belt.

5. When the tea machine is working, it should be filled with lubricating oil every day before turning.

Safety Precautions

A. This unit should be installed in a well-ventilated place.

B. The machine must be well grounded to ensure safety;

C. It is forbidden to directly pour water to rinse the surface of the frying machine and the inner barrel to prevent leakage caused by insulation failure;

D. It is forbidden to store or store flammable materials such as gasoline, alcohol, gunpowder and other flammable dangerous goods.

E. Do not use in places that are prone to water or in places with high humidity.

F. It is strictly forbidden to put your hand on the outer surface of the drum during mechanical operation to avoid burns.

Seven, the elimination of common faults

1, automatic shutdown; fuse (fuse)

1 Check if the fuse is blown, if it is blown, replace it;

2 Check if the external power supply is fully imported.

2. The number of revolutions does not reach the rated value; the voltage is too low, and the speedometer is adjusted to age.

3. If the fire is not found during the use of the product.

1. Press the ignition switch to check whether the ignition pin generates electric fire from the fire hole.

2. Check if the battery contact of the igniter is good or the voltage is too low, otherwise the battery No. 5 must be replaced.

3. Whether the ignition needle number is melted into a running position.

4. During use, the temperature rises or the temperature is out of control.

1. Check if the exhaust window is closed.

2. Check if the induction temperature probe passes through the insulation layer, otherwise it should pass through the insulation layer.

3. Check if the gas is turned on and the pressure is adjusted well (the clockwise direction is increased);

4. Check if the solenoid valve is working and the gas switch is open.